不同源漏掺杂方式对CCD放大器的影响
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Influences of Different Source-Drain Doping Methods on Performance of CCD amplifier
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    通过对CCD片上放大器不同源漏掺杂条件、方块电阻、接触电阻、有效沟道长度的分析研究, 确定了源漏工艺条件为磷离子注入能量100keV、剂量5×1015cm-2。分析了扩散、离子注入源漏掺杂对放大器直流输出的影响, 结果表明, 当宽长比为4/1时, 注入源漏掺杂制作的放大器直流输出与仿真值差异为0.28V, 优于扩散工艺。

    Abstract:

    Based on analyzing different source-drain doping methods for charge coupled-devices (CCD) amplifier, the effects of sheet resistance, contact resistance and effective channel length were researched, and the process conditions are determined as phosphorous ion implantation of 100keV with a dose of 5×1015cm2. The influences of diffusion and ion implantation on the DC output of CCD amplifier were analyzed, and the results show that the difference between the DC output and the simulation value is 0.28V when W/L ratio is 4/1, much better than the result obtained by the diffusion process.

    参考文献
    相似文献
    引证文献
引用本文

王晓强,林海青,许青,韩恒利.不同源漏掺杂方式对CCD放大器的影响[J].半导体光电,2013,34(4):603-606. Influences of Different Source-Drain Doping Methods on Performance of CCD amplifier[J].,2013,34(4):603-606.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2013-02-06
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2013-08-30
  • 出版日期:
文章二维码