Based on analyzing different source-drain doping methods for charge coupled-devices (CCD) amplifier, the effects of sheet resistance, contact resistance and effective channel length were researched, and the process conditions are determined as phosphorous ion implantation of 100keV with a dose of 5×1015cm2. The influences of diffusion and ion implantation on the DC output of CCD amplifier were analyzed, and the results show that the difference between the DC output and the simulation value is 0.28V when W/L ratio is 4/1, much better than the result obtained by the diffusion process.
参考文献
相似文献
引证文献
引用本文
王晓强,林海青,许青,韩恒利.不同源漏掺杂方式对CCD放大器的影响[J].半导体光电,2013,34(4):603-606. Influences of Different Source-Drain Doping Methods on Performance of CCD amplifier[J].,2013,34(4):603-606.