    摘要:

    传统的电荷耦合器件(CCD)处于强光环境时,会产生光晕现象; 纵向溢出漏结构的出现,满足了CCD在强光环境下的使用要求。通过对CCD的纵向溢出漏结构及其电势进行分析,发现抗晕势垒是纵向溢出漏结构能否实现抗晕功能的关键,决定了抗晕能力的强弱,而抗晕势垒受p阱注入剂量、埋沟注入剂量的影响。通过工艺仿真,确定了纵向溢出漏结构的p阱、埋沟工艺条件,根据仿真结果制造的纵向抗晕CCD抗晕能力大于100倍。

    Abstract:

    Blooming occurs when conventional CCD operates under high-light imaging situations, but it can be significantly reduced by vertical overflow drain (VOD) structure. In this paper, analysis on the VOD structure and its potential indicate that anti-blooming barrier is the main factor for the VOD structure to realize anti-blooming function and the height of anti-blooming barrier is determined by implant dose of p-well and buried channel charge-coupled device (BCCD). And the process conditions are determined by simulations, and the anti-blooming capacity of the VOD CCD fabricated based on the simulation results exceeds 100 times.