Aiming at the screening requirements of superluminesent diodes (SLD) in interferometric fiber opticgyro (I FOG), the theoretical and experimental investigations on SLD evaluation were carried out. Using the comprehensive test system, the relationship between the control parameters and characteristics of SLD was measured. The test results indicate that the equivalent resistance of TEC, power of SLD, cooling current and temperature coefficient of thermistor are the main factors affecting the matching between SLD and control parameters; if SLDs are tested closing to the practical conditions, the above characteristics can evaluate whether SLD matches the control parameters; if the above evaluation parameters can combine with the normal evaluation parameters, the SLD can be selected more completely.
参考文献
相似文献
引证文献
引用本文
殷建玲,李莉,毛少娟,刘秉琦,徐春梅.光纤陀螺光源筛选与评价方法研究[J].半导体光电,2014,35(4):581-584. Study on Screening and Evaluation Methods of Superluminesent Diode in I-FOG[J].,2014,35(4):581-584.