In view of the jitter of mechanical-optical switch, based on the models of a common uniform cantilever beam and a uniform cantilever beam carrying a mass at the free end, the dynamic response of beam under impact is researched by mode superposition method. The research indicates the reasons causing the jitter of optical power. A method of structure optimization is proposed to avoid the jitter. Experimental results prove the effectiveness of this method.
参考文献
相似文献
引证文献
引用本文
李长安,江毅,全本庆,肖清明.无抖动机械式光开关结构设计[J].半导体光电,2016,37(2):190-192. Structure Design of Mechanical-optical Switch with No Jitter[J].,2016,37(2):190-192.