In order to accurately calculate the refractive index profile of the annealed proton-exchanged (APE) lithium niobate waveguide, the buffered benzoic acid with lithium benzoate is chosen as proton-exchanged (PE) source, and the APE waveguide samples are fabricated by the annealing process. The APE model including nonlinear diffusion module and optical numeric simulation module has been established to calculate the refractive index profile of the APE waveguide and its mode effective indices, respectively. The generic method with the help of the figure of metric (FOM) which is the mean square deviation between the calculated mode effective indices and the measured values of the APE waveguides is used to extract the diffusion parameters of proton, the refractive index profile and its effective indices of the waveguide with different proton-exchanged depths and annealing time can be calculated. The experiment results show that the FOMs are below 0.001 and the calculated refractive index profiles and the experimental inverse Wentzel-Kramers-Brillouin (IWKB) profiles are in good agreement with the maximum difference of ~0.002.
参考文献
相似文献
引证文献
引用本文
王健,余才佳,纪引虎,熊恒,闫鑫.缓冲质子源LiNbO3波导折射率计算及实验[J].半导体光电,2017,38(4):546-550,556. Calculation and Experimental Demonstration of Waveguide Refractive Index of LiNbO3 Fabricated by Buffered Proton Source[J].,2017,38(4):546-550,556.