Biological signals are weak in large variation range, thus a circuit structure of fully differential trans-impedance amplifier (TIA) was designed to detect weak current. Different to traditional single-ended input structre, a high gain and fully differential two-stage amplifier was applied to realize small signal input and rail-to-rail output. Simulations were performed with 1.8V supply voltage based on CSMC 0.18μm CMOS process. Simulation results show that the TIA achieves an input current dynamic range of 100nA~10μA, a maximum transimpedance gain of 104.38dBΩ, -3dB bandwidth of 4MHz, and equivalent input noise current of 1.26pA/Hz. Simulations on transimpedance dynamic characteristics indicate that, when the input current is 100nA, the output voltage swing is 3.24mV, the power dissipation is only 250μW, and the total harmonic distortion (THD) is -49.93dB. The designed high gain and low power consumption TIA can be applied to collect very weak biological signals, and integrated as a module circuit in portable equipments.
参考文献
相似文献
引证文献
引用本文
石丹,高博,龚敏.一种用于生物信号采集的CMOS全差分前置跨阻放大器设计[J].半导体光电,2018,39(2):201-205,215. A Design of CMOS Fully Differential Trans-independence Amplifier for Biological Signal Collection[J].,2018,39(2):201-205,215.