基于萨格纳克环级联光纤布拉格光栅的双参量传感器
CSTR:
作者:
作者单位:

中国计量大学 光学与电子科技学院, 杭州 310018

作者简介:

陈慧超(1998-),男,硕士研究生,主要研究方向为光纤温度传感技术;
黄昌清(1980-),男,博士,教授,主要研究方向为光纤激光器和传感器、光子晶体光纤。

通讯作者:

黄昌清(1980-),男,博士,教授,主要研究方向为光纤激光器和传感器、光子晶体光纤。

中图分类号:

TN253

基金项目:

浙江省基础公益研究计划项目(LGG19A040001).


High-Sensitivity Dual-Parameter Sensor for Strain and Temperature Based on Sagnac Loop Cascaded with Fiber Bragg Grating
Author:
Affiliation:

College of Optical and Electronic Technology, China Jiliang University, Hangzhou 310018, CHN

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    设计了一种基于错位保偏光纤-少模光纤的萨格纳克环级联光纤布拉格光栅高灵敏度双参量传感器,可实现对应变和温度的同步测量。首先将保偏光纤沿慢轴方向与单模光纤进行错位熔接,随后将其另一端与少模光纤熔接形成复合光纤结构。通过将复合光纤结构的两端连接到至3 dB光纤耦合器,形成萨格纳克环路,萨格纳克环与光纤布拉格光栅级联形成基于错位保偏光纤-少模光纤的萨格纳克环级联光纤布拉格光栅的传感探头。实验结果表明,萨格纳克环应变灵敏度可达19.14 pm/με,温度灵敏度为-1.5 nm/℃,光纤布拉格光栅应变灵敏度为1 pm/με,温度灵敏度为10.8 pm/℃。该传感器通过双参量灵敏度矩阵实现了温度与应变的同步测量,具有灵敏度高、结构紧凑的技术优势。

    Abstract:

    A high-sensitivity dual-parameter sensor for strain and temperature measurement is developed based on a Sagnac loop cascaded with a fiber Bragg grating (FBG). The sensor employs a misaligned polarization-maintaining fiber (PMF) and few-mode fiber (FMF) structure. The strain and temperature sensing characteristics were systematically analyzed through experiments. The sensor design involves splicing a section of PMF to a single-mode fiber (SMF) with deliberate misalignment along the slow axis, followed by splicing the other end of the PMF to an FMF, creating a misaligned PMF-FMF structure. The ends of this structure were connected to a 3 dB optical fiber coupler, forming a Sagnac loop, which was then cascaded with the FBG to construct the sensing probe. Experimental results demonstrate that the strain sensitivity of the Sagnac loop reaches 19.14 pm/με, with a temperature sensitivity of -1.5 nm/°C. Additionally, the FBG exhibits a strain sensitivity of 1 pm/με, and a temperature sensitivity of 10.8 pm/°C. This sensor achieves high sensitivity for both parameters, enabling simultaneous and accurate measurement of strain and temperature.

    参考文献
    相似文献
    引证文献
引用本文

陈慧超,刘成晨,陈志萌,黄昌清.基于萨格纳克环级联光纤布拉格光栅的双参量传感器[J].半导体光电,2025,46(1):57-62. CHEN Huichao, LIU Chengchen, CHEN Zhimeng, HUANG Changqing. High-Sensitivity Dual-Parameter Sensor for Strain and Temperature Based on Sagnac Loop Cascaded with Fiber Bragg Grating[J].,2025,46(1):57-62.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-11-02
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-05-15
  • 出版日期:
文章二维码