CMOS机芯温度系数校正模型及效果验证
CSTR:
作者:
作者单位:

(1.中国计量大学光学与电子科技学院,杭州 310018;2.北京振兴计量测试研究所,北京 100074;3.南京理工大学机械工程学院,南京 210094)

作者简介:

竹学武(2000-),男,硕士研究生,主要从事光学计量、辐射测温方面的研究;占春连(1969-),女,研究员,博士生导师,现中国计量大学光学与电子科技学院院长,主要研究方向为光学计量测试技术及光学精密测试仪器研发。

通讯作者:

中图分类号:

TN216

基金项目:


CMOS Movement.Temperature.Coefficient Correction Model and Effect Verification
Author:
Affiliation:

(1. School of Optics and Electronic Science and Technology,China Jiliang University,Hangzhou 310018,CHN;2. Beijing Zhenxing Institute of Metrology and Test,Beijing 100074,CHN;3. School of Mechanical Engineering, Nanjing University of Science and Technology,Nanjing 210094,CHN)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    CMOS图像传感器具有低功耗、低成本、高集成度、高响应速度以及高测温上限等特性,在辐射测温领域中具有广泛应用。在外场试验过程中,CMOS图像传感器的机芯温度会随环境温度变化而波动,这种波动会导致背景灰度及响应系数发生变化,影响 CMOS机芯的定量能力,从而增大测温误差。基于此,文章提出一种普适性校正方法。该方法通过分别构建背景灰度及响应系数随温度变化的校正模型,实现 CMOS机芯在不同环境温度下的量值稳定性,有效提高了测温精度。实验中,利用高低温温箱模拟外场 273. 2~313. 2 K的环境温度变化范围,利用标准高温黑体,获取 CMOS图像传感器对 1 073. 2 K目标的测试数据。实验结果表明,该校正方法在实验环境温度范围内,可使 CMOS图像传感器测温的最大温差由 10.9 K降低至 2.2 K。

    Abstract:

    CMOS image sensors are characterized by low power consumption, low cost, high integration, high response speed, and high temperature ‐measurement limit, and are widely used for measuring radiation temperature. During a field experiment, the movement temperature of a CMOS image sensor fluctuates depending on the environmental temperature, which consequently alters the background grayscale and response coefficient, thus affecting the quantitative ability of the CMOS movement and increasing the temperature‐measurement error. We propose a universal calibration method to address this issue. By constructing a temperature ‐calibration model for the background grayscale and response coefficient, we achieve stable CMOS movement values under different environmental temperatures and improve the temperature‐measurement accuracy. We simulate environmental temperature changes from 273.2 to 313.2 K in an external field using high‐and low ‐temperature chambers and use a standard high‐temperature blackbody to obtain test data for a CMOS image sensor on a 1 073.2 K target. Experimental results show that this correction method can reduce the maximum temperature difference recorded by the CMOS image sensor from 10.9 to 2.2 K in a 273.2~313.2 K environment.

    参考文献
    相似文献
    引证文献
引用本文

竹学武,占春连,郭靖,高涵,王加朋,于昌本,孔德仁,商飞,徐春冬. CMOS机芯温度系数校正模型及效果验证[J].半导体光电,2025,46(3):416-422. ZHU Xuewu, ZHAN Chunlian, GUO Jing, GAO Han, WANG Jiapeng, YU Changben, KONG Deren, SHANG Fei, XU Chundong. CMOS Movement. Temperature. Coefficient Correction Model and Effect Verification[J].,2025,46(3):416-422.