Abnormal monitoring and diagnosis technology of power grid regulation behaviour based on multi-source data fusion
Author:
Affiliation:

1.Power Dispatching and Controlling Center of Guangdong Power Grid Company Limited,Guangdong,Guangzhou, China;2.Nanjing NARI Information and Communication Technology Co,Ltd,Nanjing,Jiangsu

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    主电网断路器操动机构异常监测中,多维混合特征提取困难,分类识别准确率低下,特别是在军事电网处于恶劣的场景中,信号干扰和数据不完整的问题更加突出,增加监测和故障诊断的难度。对此,研究通过变分模态分解算法与综合式梅尔倒谱系数,提出了一种多源信号特征提取方法。并在该方法的基础上,利用核主成分聚类分析与优化后的支持向量机,提出了一种新型的主电网断路器操动机构异常监测与诊断技术。实验结果表明,在正常工况下,研究方法信号特征提取标准差与均方根值分别为0.10与1.12。验证了研究方法在多源信号特征提取与噪声抑制中的有效性。此外,研究方法的最高分类识别准确率达到了97.7%。由此可知,研究所提出的方法在提高异常监测精度和诊断效率方面具有显著优势。其不仅能够为主电网断路器操动机构的异常监测与诊断提供新的技术路径,还能够为实际应用中的多源信号分析提供有效的解决方案,能够解决军事电网中,信号干扰和数据不完整的问题,提升监测与诊断的智能化水平。

    Abstract:

    Multi-dimensional hybrid feature extraction is difficult and the classification and identification accuracy is low in main grid circuit breaker operating mechanism abnormality monitoring. In this regard, the study proposes a multi-source signal feature extraction method by means of variational modal decomposition algorithm with integrated Mayer inverse spectral coefficients. On the basis of this method, a new type of abnormal monitoring and diagnosis technology for main power grid circuit breaker operating mechanism is proposed by using kernel principal component cluster analysis and optimised support vector machine. The experimental results show that under normal working conditions, the standard deviation and root mean square value of the signal feature extraction of the research method are 0.10 and 1.12, respectively, which verifies the effectiveness of the research method in multi-source signal feature extraction and noise suppression. In addition, the highest classification recognition accuracy of the research method reaches 97.7%. It can be seen that the proposed method of the research has significant advantages in improving the accuracy of anomaly monitoring and diagnostic efficiency. It can not only provide a new technical path for the anomaly monitoring and diagnosis of the main grid circuit breaker operating mechanism, but also provide an effective solution for the analysis of multi-source signals in practical applications.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-08-14
  • 最后修改日期:2025-08-14
  • 录用日期:2025-08-19
  • 在线发布日期:
  • 出版日期:
文章二维码