The team has designed an online monitoring system to address the risk of failure caused by thermal accumulation of the core component thyristor in high-voltage direct current transmission systems. To solve the problem of system level monitoring interruption caused by abnormal communication links under extreme working conditions, this paper proposes an integrated waveguide chip structure applied to the monitoring system, and designs and prepares a 4 × 16 multimode interference coupler (MMI) to achieve high-density integration of 16 channels; Developed a waveguide grating sensor (WBG) to achieve high-precision temperature measurement; Build a multi-level redundant structure by combining optical switches. The results show that the scheme achieves real-time monitoring of thyristor temperature with a measurement accuracy of ± 0.3 ℃. When the main channel fails, the backup line can be switched within 20ms, effectively solving the problem of system monitoring interruption caused by key node failures in traditional temperature monitoring systems, and significantly improving the reliability and fault tolerance of the system. The system has been tested for engineering applications at the Beijing Ultra High Voltage Experimental Base.