宇航用10KV高压光耦的可靠性验证与寿命评估
DOI:
CSTR:
作者:
作者单位:

1.中国科学院国家空间科学中心 北京;2.中国科学院国家空间科学中心

作者简介:

通讯作者:

中图分类号:

基金项目:

中国科学院可靠性保障中心种子课题基金(课题编号:CRAC-ZZKT-KY-2023-04)资助


Reliability Verification and Lifetime Evaluation of 10kV High-Voltage Optocouplers for Aerospace Applications
Author:
Affiliation:

National Space Science Center, Chinese Academy of Sciences

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为验证一款宇航应用的工业级高压光耦的固有可靠性和长期服役性能,系统开展了风险识别、环境试验与寿命评估研究。首先,通过结构分析与宇航禁限用工艺审查,识别出潜在风险。然后,通过环境试验结合物理分析手段,揭示了热效应和工艺一致性差引起的参数漂移、材料热力学响应差异导致的循环温度应力下焊接界面开裂、内部硅胶气隙缺陷诱发异常放电等关键失效机制。最后,基于线性外推法与温度?电场双应力加速模型(Arrhenius+逆幂律模型),推算其在额定工况(4000V/55℃)下的伪寿命。试验结果表明:器件在加速条件下未发生功能失效,光电流衰减小于5%;通过模型外推,得到其在实际使用条件下的伪寿命约为10.6年;结合载荷间歇工作模式,可满足8?10年宇航任务寿命需求。本研究构建了一套适用于高压光耦的可靠性验证与寿命评估方法,识别了关键风险与失效机理,并通过加速模型给出了寿命预测,为同类器件的宇航应用与国产化替代提供了技术依据与工程参考。

    Abstract:

    To verify the intrinsic reliability and long-term service performance of an industrial-grade high-voltage optocoupler for aerospace applications, a systematic study on risk identification, environmental testing, and lifetime assessment was carried out. First, potential risks were identified through construction analysis and aerospace forbidden and restricted process review. Subsequently, environmental tests combined with physical analysis revealed key failure mechanisms, including parametric drift caused by thermal effects and poor process consistency, solder-interface cracking after temperature cyclic test due to differences in material thermomechanical response, and abnormal discharge induced by internal silicone-gel void defects. Finally, based on the linear extrapolation method and a dual-stress acceleration model combining Arrhenius and inverse-power-law relationships, the pseudo-lifetime under rated operating conditions (4000?V/55?℃) was estimated. The test results show that the device did not experience functional failure under accelerated conditions, with photocurrent degradation of less than 5%. Through model extrapolation, the pseudo-lifetime under actual operating conditions was estimated to be approximately 10.6?years. Considering the intermittent operation mode of the payload, this can meet the design life requirement of 8-10?years for aerospace missions. This study establishes a reliability verification and lifetime assessment framework suitable for high-voltage optocouplers, identifies key risks and failure mechanisms, and provides lifetime predictions through accelerated models, offering technical support and engineering reference for the aerospace application and domestic substitution of similar devices.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-12-18
  • 最后修改日期:2026-01-10
  • 录用日期:2026-01-21
  • 在线发布日期:
  • 出版日期:
文章二维码