Abstract:A microbolometer based on standard CMOS technology enables monolithic integration of the sensor and readout circuitry, offering a simplified fabrication process and low cost; it is therefore well suited for large-format imaging array fabrication. Post-CMOS processing is a critical step for forming the thermally isolated cavity in this type of microbolometer. In this study, the effects of silicon powder and ammonium persulfate additions in a wet-etching process on the fabrication of the thermal isolation cavity were investigated. The results showed that, when the silicon substrate was etched in a 5 wt% tetramethylammonium hydroxide (TMAH) solution, adding silicon powder effectively suppressed corrosion of the Al electrodes, whereas incorporating ammonium persulfate mitigated the hindering effect of hydrogen bubbles generated during etching, thereby significantly improving the planarity of the etched Si surface. Experimental results further indicated that the optimal addition amounts were 0.8 g of silicon powder and 0.2 g of ammonium persulfate in the TMAH solution. Ultimately, a CMOS microbolometer array structure with well-suspended membranes was successfully fabricated using the optimized etching solution.