    摘要:

    铟镓砷短波红外焦平面探测器性能的精确评估对于应用系统的成像质量与定量化分析至关重要。为验证积分球均匀光源在铟镓砷短波红外焦平面探测器特性参数测试中的可行性,采用积分球均匀光源与高温黑体分别作为均匀光源,对不同阵列规模与像元尺寸的探测器进行响应率非均匀性与有效像元率对比测试。实验结果表明,积分球均匀光源测试所得响应率非均匀性指标均优于黑体光源,其中在 2 560×2 048阵列规模下,响应率非均匀性由 4. 57%降至2. 85%,相对改善幅度达 60. 35%;有效像元率由 99. 978%提升至 99. 984%。进一步分析表明,积分球均匀光源可有效消除黑体光源因朗伯辐射特性引入的辐照度分布不均与背景噪声影响,测试结果更接近器件真实性能,且操作更为便捷。

    Abstract:

    To verify the feasibility of using an integrating spherical uniform light source for testing the characteristic parameters of indium gallium arsenide short-wave infrared focal plane detectors,comparative tests were conducted using an integrating spherical uniform light source and a high-temperature blackbody as uniform light sources. The response non-uniformity and effective pixel ratio of detectors with different array sizes and pixel dimensions were evaluated. Experimental results show that the integrating sphere uniform light source yields superior response non-uniformity compared with the blackbody source. For a detector with a 2 560 × 2 048 array,the response non-uniformity decreases from 4. 57% to 2. 85%,which represents a relative improvement of 60. 35%, while the effective pixel ratio increases from 99. 978% to 99. 984%. The analysis indicates that the integrating sphere uniform light source effectively eliminates the irradiance non-uniformity and background noise introduced by the Lambertian characteristics of the blackbody source,thus providing test results that reflect the actual performance of the device more accurately. Furthermore,the integrating spherical uniform light source offers greater operational convenience compared with the blackbody source. Considering its advantages,the integrating spherical uniform light source may be included as an optional light source in relevant testing standards.

    参考文献
    相似文献
    引证文献
引用本文

王力霞,冯巍巍,陈扬,乔建社,徐俊杰. InGaAs短波红外焦平面特性参数测试方法[J].半导体光电,2026,47(2):315-319. WANG Lixia, FENG Weiwei, CHEN Yang, QIAO Jianshe, XU Junjie. Test Methods for Characteristic Parameters of InGaAs Short-Wave Infrared Focal Plane Arrays[J].,2026,47(2):315-319.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-09-01
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-05-25
  • 出版日期:
文章二维码