    摘要:

    为验证一款宇航应用的工业级高压光耦的固有可靠性和长期服役性能,系统开展了风险识别、环境试验与寿命评估研究。首先,通过结构分析与宇航禁限用工艺审查,识别出潜在风险。然后,通过环境试验与物理分析,揭示了以下关键失效机制:由热效应与工艺一致性差引发的参数漂移;由材料热力学响应差异导致在循环温度应力作用下的焊接界面开裂;以及由内部硅胶气隙缺陷诱发的异常放电。最后,基于线性外插法与温度 -电场双应力加速模型,推算其在额定工况(4 000 V/55℃)下的伪寿命。试验结果表明:器件在加速条件下未发生功能失效,光电流衰减小于 5%;通过模型外推,得到其在实际使用条件下的伪寿命约为 10. 6年;结合载荷间歇工作模式,可满足 8~10年宇航任务寿命需求。该研究构建了一套适用于高压光耦的可靠性验证与寿命评估方法,识别了关键风险与失效机理,并通过加速模型给出了寿命预测,为同类器件的宇航应用与国产化替代提供了技术依据与工程参考。

    Abstract:

    In this study,systematic risk identification,environmental testing,and lifetime assessment were performed to verify the intrinsic reliability and long-term service performance of an industrial-grade high-voltage optocoupler for aerospace applications. First, potential risks were identified through construction analysis and a review of aerospace forbidden and restricted processes. Subsequently,environmental tests combined with physical analyses revealed key failure mechanisms, including parametric drift caused by thermal effects and poor process consistency,solder-interface cracking after temperature cycling tests(due to differences in material thermomechanical responses), and abnormal discharge induced by internal silicone-gel void defects. Finally,based on a linear extrapolation method and a dual-stress acceleration model combining Arrhenius and inverse power law relationships,the pseudo-lifetime under rated operating conditions(4 000 V/55℃)was estimated. The test results showed that the device did not experience functional failure under accelerated conditions,with photocurrent degradation of less than 5%. The pseudo-lifetime estimated under actual operating conditions via model extrapolation was approximately 10. 6 years. Considering the intermittent operation mode of the payload,this pseudo-lifetime satisfies the 8~10 year design life requirement for aerospace missions. This study establishes a reliability verification and lifetime assessment framework suitable for high-voltage optocouplers,reveals key risks and failure mechanisms, and provides lifetime predictions through accelerated models, offering technical support and an engineering reference for aerospace applications and the domestic substitution of similar devices.

    参考文献
    相似文献
    引证文献
引用本文

李瑞轩,张泽迁,翁正,朱永鑫,杜磊,范晓军,李哲,刘红民.宇航用 10 kV高压光耦的可靠性验证与寿命评估[J].半导体光电,2026,47(2):388-395. LI Ruixuan, ZHANG Zeqian, WENG Zheng, ZHU Yongxin, DU Lei, FAN Xiaojun, LI Zhe, LIU Hongmin. Reliability Verification and Lifetime Assessment of 10 kV High-Voltage Optocouplers for Aerospace Applications[J].,2026,47(2):388-395.