Abstract:Irregular macrobending loss is difficult to quantify in non-intrusive optical power measurements of optical fiber networks. To address this problem, a finite element method is proposed for calculating irregular macrobending loss. To validate the proposed method, an irregularly bent fiber model constrained by a representative fixture was developed using the electromagnetic waves, beam envelopes interface in COMSOL Multiphysics. S-parameters were used to quantify the macrobending loss. The fixture was then fabricated by 3D printing, and an experimental setup was established to validate the proposed method. The results show that the loss calculated by finite element analysis for the representative fixture is 1.15 dB. This value is in reasonable agreement with the experimentally measured average loss of 1.44 dB. On this basis, the effect of the fixture angle on bending loss was investigated over an angular range of 70° to 120°. The macrobending loss first increased and then decreased as the fixture angle increased. When the fixture angle was between 85° and 95°, the leaked optical power was sufficient to meet the response requirements of the photodetector, while the loss of the backbone fiber link remained within the allowable safety range of 1 dB to 3 dB. This study provides a reliable method for calculating macrobending loss under irregular fiber-bending conditions. It also provides a useful reference for determining the leakage ratio and the optimal fixture angle range in non-intrusive optical power measurements.