基于有限元分析的光纤不规则宏弯损耗计算方法与夹角优化
DOI:
CSTR:
作者:
作者单位:

1.华北电力大学 电气与电子工程学院;2.国网福建省电力有限公司;3.国网福建省电力有限公司电力科学研究院

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目(面上项目,重点项目,重大项目)


Finite Element Calculation of Irregular Macrobending Loss in Optical Fibers and Optimization of the Fixture Angle
Author:
Affiliation:

1.School of Electrical and Electronic Engineering,North China Electric Power University;2.State Grid Fujian Electric Power Co,Ltd,Fuzhou ,CHN;3.State Grid Fujian Electric Power Co,Ltd Electric Power Research Institute

Fund Project:

The National Natural Science Foundation of China (General Program, Key Program, Major Research Plan)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对光纤网络非侵入式光功率测量中不规则弯曲损耗难以定量计算的问题,本文提出了一种基于有限元分析的光纤不规则宏弯损耗计算方法。为验证该方法的有效性,基于COMSOL中的波束包络法模块构建了某典型夹具约束下光纤的不规则弯曲模型,引入S参数实现了宏弯损耗的量化计算,采用3D打印技术制作该典型夹具并搭建实验系统进行了验证。结果表明,该典型夹具的有限元计算损耗为1.15 dB,实验测得的平均损耗为1.44 dB,二者基本吻合。在此基础上,对典型夹具夹角在70°~120°范围内变化时夹角对弯曲损耗的影响进行了研究,结果表明,光纤宏弯损耗随夹具夹角的增大呈现出先增大后减小的趋势,当夹具夹角在85°~95°的范围内变化时,产生的泄漏光功率既能满足光电探测器的响应需求,又能使主干光纤链路的损耗处于1 dB~3 dB的安全允许阈值范围内。本文为不规则弯曲时泄漏光功率的计算提供了一种可靠方法,并为典型夹具下泄漏比例和最佳夹角范围的确定提供参考。

    Abstract:

    Irregular macrobending loss is difficult to quantify in non-intrusive optical power measurements of optical fiber networks. To address this problem, a finite element method is proposed for calculating irregular macrobending loss. To validate the proposed method, an irregularly bent fiber model constrained by a representative fixture was developed using the electromagnetic waves, beam envelopes interface in COMSOL Multiphysics. S-parameters were used to quantify the macrobending loss. The fixture was then fabricated by 3D printing, and an experimental setup was established to validate the proposed method. The results show that the loss calculated by finite element analysis for the representative fixture is 1.15 dB. This value is in reasonable agreement with the experimentally measured average loss of 1.44 dB. On this basis, the effect of the fixture angle on bending loss was investigated over an angular range of 70° to 120°. The macrobending loss first increased and then decreased as the fixture angle increased. When the fixture angle was between 85° and 95°, the leaked optical power was sufficient to meet the response requirements of the photodetector, while the loss of the backbone fiber link remained within the allowable safety range of 1 dB to 3 dB. This study provides a reliable method for calculating macrobending loss under irregular fiber-bending conditions. It also provides a useful reference for determining the leakage ratio and the optimal fixture angle range in non-intrusive optical power measurements.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-05-30
  • 最后修改日期:2026-08-05
  • 录用日期:2026-08-24
  • 在线发布日期:
  • 出版日期:
文章二维码