    摘要:

    随着光纤通信、光电感知终端及智能电子设备在电网调度系统中的广泛接入,调度操作复杂性不断提升,跨级调度指令的准确及时执行对电网安全稳定运行至关重要。针对电网调度场景的光电感知传输系统存在指令语义歧义、执行状态不一致、闭环响应滞后等问题,提出一种调度指令全流程监控与跨级执行校核系统。该系统构建分层监控体系,覆盖指令编制、下达、执行、反馈全生命周期,通过边缘计算实现光电感知数据与现场设备运行数据的预处理和实时传输,并引入区块链技术保障调度指令传输的防篡改与可追溯。进一步设计双向协同校核机制,融合状态估计、规则引擎、长短期记忆网络(Long Short Term Memory Network, LSTM)与词向量模型(Word to Vector, Word2Vec)智能算法,实现上下级调度间的前置校核与反向校核,降低跨级语义歧义与误操作风险。该技术对指令格式错误、参数越限、设备状态冲突的识别准确率分别为98.0%、99.0%和99.0%,较传统方案语义匹配度提升25%;正常工况下端到端延迟低至32 ms,故障工况延迟控制在70 ms以内,较传统方案降低50%;修正后达标率控制在98.8%~99.3%,故障工况闭环恢复率提高15%。结果表明,所提技术能够显著提升光电感知数据支撑下调度指令执行的准确性、实时性与安全性,为电网跨级调度全流程监控与智能校核提供有效技术支撑。

    Abstract:

    With the widespread integration of fiber-optic communication, optoelectronic sensing terminals, and intelligent electronic devices into the power grid dispatching system, the complexity of dispatching operations has been continuously increasing. The accurate and timely execution of cross-level dispatching instructions is crucial for the safe and stable operation of the power grid. Addressing issues such as instruction semantic ambiguity, inconsistent execution status, and delayed closed-loop response in the optoelectronic sensing transmission system for power grid dispatching scenarios, a system for full-process monitoring and cross-level execution verification of dispatching instructions is proposed. This system establishes a hierarchical monitoring framework covering the entire lifecycle of instruction preparation, issuance, execution, and feedback. It utilizes edge computing to achieve preprocessing and real-time transmission of optoelectronic sensing data and on-site equipment operation data, and incorporates blockchain technology to ensure tamper-proof and traceable transmission of dispatching instructions. Furthermore, a bidirectional collaborative verification mechanism is designed, integrating intelligent algorithms such as state estimation, rule engines, Long Short Term Memory Network (LSTM), and Word to Vector (Word2Vec) models, to achieve pre-verification and reverse verification between superior and subordinate dispatching levels, reducing the risk of cross-level semantic ambiguity and misoperations. The technology achieves recognition accuracy rates of 98.0%, 99.0%, and 99.0% for instruction format errors, parameter violations, and equipment state conflicts, respectively, representing a 25% improvement in semantic matching compared to traditional schemes. Under normal operating conditions, the end-to-end delay is as low as 32 ms, and the delay under fault conditions is controlled within 70 ms, a 50% reduction compared to traditional schemes. After correction, the compliance rate is maintained between 98.8% and 99.3%, and the closed-loop recovery rate under fault conditions is improved by 15%. The results indicate that the proposed technology significantly enhances the accuracy, real-time performance, and safety of dispatching instruction execution supported by optoelectronic sensing data, providing effective technical support for full-process monitoring and intelligent verification of cross-level dispatching in the power grid.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-07-03
  • 最后修改日期:2026-07-03
  • 录用日期:2026-07-08
  • 在线发布日期:
  • 出版日期:
文章二维码