Abstract:This paper proposes a multi-point synchronous measurement and high-precision demodulation method for optical electric field based on spectral reconstruction. A multi-point synchronous electric field measurement system based on lithium niobate crystals is designed and constructed. By introducing a discrete cavity length transform algorithm to reconstruct the spectrum, this method effectively suppress spectrum broadening, sharpens frequency-domain peaks, and resolves the issue of multi-spectral peak aliasing. High-precision measurement of multi-node electric fields is achieved within the range of 0~1100 kV/m. Specifically, the sensitivity of the fundamental Vernier envelope stabilizes at 2.84±0.0017 nm/(V·μm?1) with a repeatability error of 2.20×10?3, while the sensitivity of the harmonic Vernier envelope stabilizes at 3.37±0.0011 nm/(V·μm?1) with a repeatability error of 6.54×10??. Furthermore, the interference noise characteristics of the system are analyzed, providing a theoretical basis for system optimization. This research offers a practical technical approach for high-precision, quasi-distributed optical electric field measurement in complex electrical environments.