Abstract:To address the periodic measurement errors induced by non-ideal optical-path characteristics and the limited dynamic response of reflective fiber-optic current transformer (FOCT) over a wide measurement range, a periodic optical-path error compensation method combined with adaptive parameter control is proposed. Three types of non-ideal optical-path factors are analyzed using Jones matrices. A simplified sine-series compensation model is established based on Fourier spectral analysis and the least-squares method, and real-time computation is implemented using the coordinate rotation digital computer (CORDIC) algorithm. Meanwhile, the integral gain is adaptively adjusted according to the current state and feedback phase error. Experimental results show that, with a rated current of 180 kA, the ratio error satisfies the accuracy requirements for a 0.2S-class current transformer. Under adaptive control, the rise time is 40 μs and the bandwidth reaches 8.75 kHz. In the 500 kA pulse-current test, the overshoot is only 0.8% and the settling time is 1.42 ms, demonstrating effective improvements in both measurement accuracy and dynamic performance of the FOCT.