1.Lanzhou University,School of Materials and Energy,Lanzhou of Gansu Prov;2.National Key Laboratory of Intense Pulsed Radiation Simulation and Effect Northwest Institute of Nuclear Technology,Xian of Shaanxi Prov;3.Xiangtan University,School of Materials Science and Engineering,Xiangtan of Hunan Prov

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    在西安质子重离子应用装置上开展了6T背照CMOS图像传感器(CIS)的重离子辐照实验,通过对Ar离子辐照CIS的暗场图像进行原位在线实时采集,获取了Ar离子辐照诱发CIS单粒子瞬态(SET)效应的典型实验现象,比较了CIS不同积分时间、不同辐照注量率、不同输出增益对SET效应的影响,分析了SET效应的实验规律,给出了SET效应诱发CIS暗场平均灰度值和暗信号不均匀性随积分时间增大的变化曲线,阐明了SET效应诱发CIS暗信号尖峰(亮点、亮斑、亮线)产生的物理机制。实验结果表明:随着积分时间的增长,重离子辐照诱发的SET导致CIS暗场输出图像质量从受到干扰到严重降级,直至功能失效;重离子辐照注量率不同,SET效应诱发CIS的典型特征差别明显;CIS选取不同输出增益工作模式对SET效应也会产生影响,高增益读出和低增益读出呈现的SET输出暗场图差别明显,两者结合可构建较为完整的SET事件幅度谱。研究结果为CIS的SET效应仿真模拟、辐照损伤预估、抗辐射加固设计提供了理论依据和实验支撑。

    Abstract:

    The experiment of a 6T back-illuminated CMOS image sensor (CIS) irradiated by heavy ions was carried out at Xian Proton and Heavy Ion Application Facility (XiPAF). By performing in-situ real-time acquisition of dark-field images of the CIS irradiated by Ar ions, typical experimental phenomena of single event transient (SET) effects induced by Ar ion radiation in the CIS were obtained. The effects of different integration times, different radiation fluence rates, and different output gains on the SET effect were compared. The experimental results of the SET effect were analyzed, and the variation curves of the dark-field average gray value and dark signal non-uniformity induced by the SET effect versus integration time were provided. The physical mechanism of dark signal spikes (bright spots, bright patches, and bright lines) induced by the SET effect in the CIS was demonstrated. The experimental results show that as the integration time increases, the SET effect induced by heavy ion radiation causes the quality of the CIS dark-field output image to degrade from interference to severe degradation, and eventually to functional failure. Different heavy ion radiation fluence rates result in distinct typical characteristics of the SET effect in the CIS. The selection of different output gain operating modes also affects the SET effect, with significant differences in the SET output dark-field images between high-gain readout and low-gain readout. Combining these two modes can be used to construct a relatively complete SET event amplitude spectrum. The research provides a theoretical basis and experimental support for the simulation of SET effects in CIS, irradiation damage prediction, and radiation-hardening design.